Applications
Roxar 2600 MPFM M:
Impedance measurementSingle well applicationsDirect well head monitoring and trending of oil, water and gasFractions and rates0-85% GVF0-100% WLRFlow velocity 5-25 m/s
Roxar 2600 MPFM MV:Impedance and venturi measurementSingle or multi well applicationsFlow rates for oil, water and gas over a wide range of applications0-100% GVF0-100 WLRFlow velocity 2-40 m/s
Roxar 2600 MPFM MVG:Impedance, venturi and gamma density measurementSingle or multi well applicationsFlow rates for oil, water and gas over the full range of applications0-100% GVF0-100% WLRFlow velocity 1-40 m/s
Installation
Vertical upwards flow
Meter Sizes
ID 1 1/2 in (35mm) to ID8 in (173mm)
Design Pressure
Up to 5,000 psi (345 bar)
Design Temperature
-4 °F (-20 °C) to 266 °F (130 °C)
Lower minimum temperatures can be accommodated, assessed on a case by cases basic.
Process Wetted Material
Duplex UNS S31803
Stainless steel UNS S31600
Super duplex UNS S32760
Inconel 625 UNS N06625
PEEK natural
Flange Connection
ANSI flanges or hubs with clamp connectors
Gamma measurement (when applicable)
Compact gamma system
Source: Cs-137
2, 5 or 8.3 mCi
Half-life 30.1 years
Power Supply
18-30 VDC
100-240 VAC
Power consumption: < 20 W
Communication Protocol
Modbus RTU
Modbus TCP
HTTP
Communication Interface
RS-485
Ethernet
Mounting
Painted aluminium Ex d housing for hazardous area
SS 316L Ex d housing for hazardous area
Certifications/Approvals
Hazardous area certification: ATEX, IECEx, cCSAus
Design code: ASME B16.5, ASME B31.3
Material specification compliance: ASME B31.3
Sour service wetted parts: NACE MR 0175, ISO 15156